Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Sci Rep ; 14(1): 1659, 2024 01 18.
Artículo en Inglés | MEDLINE | ID: mdl-38238396

RESUMEN

When treating ankle fractures, the question of syndesmosis complex involvement often arises. So far, there is no standardized method to reliably detect syndesmosis injuries in the surgical treatment of ankle fractures. For this reason, an intraoperative syndesmosis-test-tool (STT) was developed and compared to the recommended and established hook-test (HT). Tests were performed on cadaveric lower legs (n = 20) and the diastasis was visualized by 3D camera. Tests were performed at 50, 80, and 100 N in native conditions and four instability levels. Instability was induced from anterior to posterior and the reverse on the opposite side. The impact on diastasis regarding the direction, the force level, the instability level, and the device used was checked using a general linear model for repeated measurement. The direction of the induced instability showed no influence on the diastasis during the stability tests. The diastasis measured with the STT increased from 0.5 to 3.0 mm depending on the instability, while the range was lower with the HT (1.1 to 2.3 mm). The results showed that the differentiation between the instability levels was statistically significantly better for the developed STT. The last level of maximum instability was significantly better differentiable with the STT compared to the HT. An average visualizable diastasis of more than 2 mm could only be achieved at maximum instability. In conclusion, the newly developed STT was superior to the commonly used HT to detect instability.


Asunto(s)
Fracturas de Tobillo , Traumatismos del Tobillo , Inestabilidad de la Articulación , Humanos , Tobillo , Inestabilidad de la Articulación/diagnóstico , Articulación del Tobillo , Traumatismos del Tobillo/diagnóstico , Traumatismos del Tobillo/cirugía
2.
J Clin Med ; 12(14)2023 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-37510697

RESUMEN

The hook test is a widely used intraoperative method for assessing syndesmosis stability. However, there are no recommendations regarding the force required to perform this test. Furthermore, the reliability of the test is unclear. Ten experienced surgeons performed hook tests on a cadaver bone model. The applied forces were recorded in a blinded manner. In addition, standardized hook tests with defined forces (50, 80, and 100 N) were performed on 10 pairs of cadaver lower legs and the syndesmosis was sequentially destabilized. Diastasis of the syndesmosis was recorded using an optical 3D camera system. A median force of 81 N (Range: 50 N-145 N) was applied. A proportion of 82% of the tests showed a force < 100 N. The data showed good intraraterreliability and poor interraterreliability. In the standardized investigation of the hook test on the cadaver bone model, both the force and the instability of the syndesmosis had a significant influence on the syndesmosis diastasis. Nevertheless, even with maximum instability of the syndesmosis, diastasis > 2 mm could only be measured in 12 of the 19 evaluable specimens. The widely used hook test shows a high variability when performed in practice. Even in a standardized manner, the hook test cannot detect a relevant syndesmosis injury.

3.
J Clin Med ; 12(2)2023 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-36675627

RESUMEN

In the treatment of ankle fractures, complications such as wound healing problems following open reduction and internal fixation are a major problem. An innovative alternative to this procedure offers a more minimally invasive nail stabilization. The purpose of this biomechanical study was to clarify whether this method was biomechanically comparable to the established method. First, the stability (range of motion, diastasis) and rotational stiffness of the native upper ankle were evaluated in eight pairs of native geriatric specimens. Subsequently, an unstable ankle fracture was created and fixed with a locking plate or a nail in a pairwise manner. The ankles showed significantly less stability and rotational stiffness properties after nail and plate fixations than the corresponding native ankles (p < 0.001 for all parameters). When comparing the two methods, both showed no differences in their range of motion (p = 0.694) and diastasis (p = 0.166). The nail also presented significantly greater rotational stiffness compared to the plate (p = 0.001). However, both fixations remained behind the native stability and rotational stiffness. Due to the comparable biomechanical properties of the nail and plate fixations, an early weight-bearing following nail fixation should be assessed on a case-by-case basis considering the severity of fractures.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...